מפרט
Specifications HD110C
Display 3-1/2 digit LCD, 1999 counts, with annunciators and menu features Polarity Indication Automatic Input overload indication 1
Low Battery Indication ; < 50 hours battery life remain, accuracy is no longer guaranteed Display Update Rate 2.5/sec, nominal Oper. Temp. 0 °C to +50 °C, (< 75 % R.H.) Storage Temp -20 °C to 60 °C, 0 to 80 % RH, battery removed
Temperature coefficient
0.1 x (spec. accuracy)/°C (0 ° to 18 °C and 28° to 50 °C) all functions and ranges except for mVDC 0.3 x (spec. accuracy)/°C (0 ° to 18 °C and 28° to 50 °C) for mVDC Altitude Up to 2000 m — indoor use Fuse F 2 A/1500 V fuse (8 mm x 65 mm), I.R. 30 kA – Amprobe p/n FP700 Power Standard 9 V battery, NEDA 1604, JIS 006P,IEC 6F22 Auto Power-Down Meter powers down after approx. 30 min. of inactivity. Battery Life 250 hours typical with carbon-zinc, 500 hours typical with alkaline Power 1.5 volt battery x2, R03/SIZE AAA. Isolated battery compartment Battery life 150 hours typical with carbon-zinc. 300 hours typical with alkaline Dimensions, with holster (H x W x D) 200 x 102 x 59 mm (7.9 in x 4.0 in x 2.3 in) Weight (incl. battery) 642 g (20 oz) Safety Meets EN 61010-1 CAT IV 1000 V (1500 V DC max) Class II, EN 60529:IP67 EMC Meets EN 61326-1 Case material Flame retardant, high-impact thermoplastic
Included Accessories
Heavy Duty CAT IV 1000 V Test leads with threaded alligator clips (TL1500), battery (in instrument), hex wrench in holster, MagneGrip flex strap and User Manual
HD110C ELECTRICAL SPECIFICATIONS
DC Volts
Ranges 200 mV, 2 V, 20 V, 200 V, 1500 V Resolution 0.1 mV Accuracy ±(0.1 % rdg+2 dgts) Input Impedance 10 MΩ OL Protection 1500 V dc/1000 V ac rms
Transient Protection
12 kV impulse (1.2 μS/50 μS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV.
AC Volts (45 Hz to 2 kHz)
Ranges 200 mV, 2 V, 20 V, 200 V, 1000 V Resolution 0.1 mV
Accuracy
200 mV to 200 V (45-500 Hz) ±(0.8 % rdg+4 dgts) 200 mV to 200 V (500 Hz-2 kHz) ±(1.5 % rdg+5 dgts) 1000 V (50-60 Hz) ±(0.8 % rdg+4 dgts) 1000 V (60-500 Hz) ±(1.5 % rdg+5 dgts) Input Impedance 10 MΩ OL Protection 1500 V dc/1000 V ac rms
Transient Protection
12 kV impulse (1.2 μS/50 μS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV.
DC Current
Ranges 200 μA, 2 mA, 20 mA, 200 mA, 2 A Resolution 0.1 μA
Accuracy
200 μA to 20 mA ±(0.5 % rdg+2 dgts) 200 mA to 2 A ±(1.0 % rdg+2 dgts)
DC Current (cont.)
Voltage Burden
250 mV max. (1 mV/1 μA on 200 μA Range) (100 mV/1 mA on 2 mA Range) (10 mV/1 mA on 20 mA Range) (1.5 mV/1 mA on 200 mA Range) (500 mV/1 A on 2 A Range) OL Protection A Input (F 2 A/1500 V, size 8 x 65 mm IR fast blow ceramic) (FP 700)
AC Current (45 Hz to 1 kHz)
Ranges 200 μA, 2 mA, 20 mA, 200 mA, 2 A Resolution 0.1 μA
Accuracy
200 μA to 20 mA ±(0.8 % rdg+4 dgts) 200 mA to 2 A ±(1.2 % rdg+4 dgts) Voltage Burden 250 mV max. (1 V on 2 A range) OL Protection same as DC Current
ACD-23SW ELECTRICAL SPECIFICATIONS
Resistance
Ranges 200 Ω, 2 kΩ, 20 kΩ, 200 kΩ, 2 MΩ, 20 MΩ Resolution 0.1 Ω
Accuracy
200 Ω ±(0.5 % rdg+4 dgts) 2 kΩ to 200 kΩ ±(0.3 %rdg+2 dgts) 2 MΩ ±(1.0 % rdg+4 dgts) 20 MΩ ±(2.0 %rdg+4 dgts OL Protection 1500 V dc/1000 V ac rms
Open Circuit Voltage
200 Ω range 3.0 V dc typical all other ranges 0.3 V dc typical.
Diode/Continuity Test
Test Current 1m A dc typical Test/Open Circuit Voltage 3.0 V dc Typical Diode Accuracy ±(1.5 % rdg+2 dgts) Continuity Audible Threshold <50 Ω ± 25 Ω Response Time <100 msec OL Protection 1500 V dc/1000 V ac rms